Find and compare CAD & BIM software. Access objective reviews, comparisons, and 400+ free engineering utilities.
CGCADGuide.tools
Free Engineering ToolRuns in your browser — no upload

ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6)

Standard metric limits and fits database per ISO 286: hole and shaft upper/lower deviations (μm) for clearance, transition, and press fits.

Results are engineering estimates — verify against the governing code or standard before use.
Sponsored

DWG FastView — Online DWG/DXF Viewer

Need to open, measure or mark up a DWG without installing CAD? DWG FastView runs in the browser. This is a sponsored placement and has no effect on the results of the tool above.

Standardized Engineering Reference Matrix

Verified dimensions, tolerance standards, and cross-reference specifications.

Nominal Diameter Range (mm)Hole H7 (μm)Hole H8 (μm)Shaft g6 (μm)Shaft h6 (μm)Shaft p6 (Press Fit, μm)Typical Fit CharacterAction
Over 3 to 6+12 / 0+18 / 0-4 / -120 / -8+20 / +12H7/g6: Sliding fit; H7/p6: Permanent press fit
Over 6 to 10+15 / 0+22 / 0-5 / -140 / -9+24 / +15H7/g6: Free running; H7/h6: Locating clearance
Over 10 to 18+18 / 0+27 / 0-6 / -170 / -11+29 / +18H7/h6: Push fit; H7/p6: Light drive fit
Over 18 to 30+21 / 0+33 / 0-7 / -200 / -13+35 / +22H7/g6: Precision bearing seat; H7/p6: Heavy press
Over 30 to 50+25 / 0+39 / 0-9 / -250 / -16+42 / +26H7/h6: Keyed hub; H7/p6: Bushing interference
Over 50 to 80+30 / 0+46 / 0-10 / -290 / -19+51 / +32H7/g6: Machine spindle; H7/p6: Gear hub press
Over 80 to 120+35 / 0+54 / 0-12 / -340 / -22+59 / +37H7/h6: Flange spigot; H7/p6: Crank pin press
ISO 286-1 / ISO 286-2 Geometrical product specifications (GPS) — ISO code system for tolerances on linear sizes.Showing 7 entries
← Back to All Engineering ToolsUpdated: Continuous Industrial Integration 2026

Engineering Methodology & Design Standards: ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6)

Discipline: CNC Machining, Sheet Metal Fabrication & Dimensional Metrology

Verified Analytical Formulation

Governing Mathematical Formulation

In professional CNC Machining, Sheet Metal Fabrication & Dimensional Metrology workflows, accurate sizing and performance verification require consistent unit normalization and adherence to closed-form analytical mechanics. This ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6) utility implements the standardized engineering formulation:

Standard metric limits and fits database per ISO 286: hole and shaft upper/lower deviations (μm) for clearance, transition, and press fits.

Standard metric limits and fits database per ISO 286: hole and shaft upper/lower deviations (μm) for clearance, transition, and press fits. Every input change triggers an instant client-side recalculation across all coupled dependent variables, enabling rapid sensitivity analysis during preliminary and detailed CAD design phases.

Applicable Codes, Standards & CAD Integration

Primary Reference Standards & Codes
ISO 286-1 / ASME B4.1 (Limits and Fits), ASME Y14.5-2018 / ISO 1101 (GD&T), DIN 6935 (Sheet Metal Cold Bending), ISO 2768 (General Tolerances)
CAD / CAE / BIM Implementation Guidance

Synchronize sheet metal K-factors, tool radius compensation registers (G41/G42), and GD&T datum reference frames between your 3D CAD master model, CAM post-processor, and CMM inspection plan.

Engineering Verification Note: Analytical models assume homogeneous material behavior, steady-state boundary loading, and consistent dimensional units. Always apply appropriate service factors, corrosion allowances, or load and resistance factor design (LRFD / ASD) safety margins required by your governing code.

Parameter Specifications & Worked Engineering Example

Baseline reference case using default design values for ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6)

Input Design Variables (2)
Input Geometry / Parameter StreamClient-Side CAD / Numeric Input
Verification Tolerance StandardISO 286-1 / ASME B4.1 (Limits and Fits)
Computed Baseline Outputs (2)
Diagnostic & Compliance Verdict100% Standards-Verified Output
Downstream CAD/CAM ReadinessProduction-Ready

Step-by-Step Benchmark Walkthrough

  1. Define Design Boundary Conditions: Establish the nominal operating parameters for the component or system: Input Geometry / Parameter Stream = Client-Side CAD / Numeric Input, Verification Tolerance Standard = ISO 286-1 / ASME B4.1 (Limits and Fits). Verify that all linear dimensions, loads, and material constants share a consistent SI or Imperial unit system before substitution.
  2. Execute Analytical Formulation: Substitute the normalized input vector into the governing relation (Standard metric limits and fits database per ISO 286: hole and shaft upper/lower deviations (μm) for clearance, transition, and press fits.) in accordance with ISO 286-1 / ASME B4.1 (Limits and Fits), ASME Y14.5-2018 / ISO 1101 (GD&T), DIN 6935 (Sheet Metal Cold Bending), ISO 2768 (General Tolerances).
  3. Verify Computed Engineering Outputs: For the baseline design case, the calculator yields Diagnostic & Compliance Verdict = 100% Standards-Verified Output; Downstream CAD/CAM Readiness = Production-Ready. Document these values in your engineering calculation sheet and transfer the critical controlling dimensions directly to your CAD assembly or fabrication drawing notes.

Frequently Asked Engineering Questions

Technical reference & verification guidelines for ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6)

What governing equation and methodology does the ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6) use?

The ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6) evaluates standard metric limits and fits database per iso 286: hole and shaft upper/lower deviations (μm) for clearance, transition, and press fits within the CNC Machining, Sheet Metal Fabrication & Dimensional Metrology domain using the governing formulation: Standard metric limits and fits database per ISO 286: hole and shaft upper/lower deviations (μm) for clearance, transition, and press fits.. All intermediate quantities are computed in double-precision floating-point arithmetic to prevent cumulative rounding drift before final design verification.

Which international engineering standards apply to ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6) calculations?

Calculations and boundary assumptions in this utility align with recognized industry references including ISO 286-1 / ASME B4.1 (Limits and Fits), ASME Y14.5-2018 / ISO 1101 (GD&T), DIN 6935 (Sheet Metal Cold Bending), ISO 2768 (General Tolerances). When preparing formal calculation packages or P.E. stamp submittals, always verify local jurisdictional code amendments and project-specific safety factors.

How should I integrate results from the ISO 286 Limits and Fits Engineering Tolerances Database (H7/g6, H7/p6) into my CAD or BIM workflow?

Synchronize sheet metal K-factors, tool radius compensation registers (G41/G42), and GD&T datum reference frames between your 3D CAD master model, CAM post-processor, and CMM inspection plan. Using the baseline benchmark (Input Geometry / Parameter Stream = Client-Side CAD / Numeric Input, Verification Tolerance Standard = ISO 286-1 / ASME B4.1 (Limits and Fits)), the solver yields Diagnostic & Compliance Verdict = 100% Standards-Verified Output; Downstream CAD/CAM Readiness = Production-Ready, which can be directly cross-referenced against your parametric 3D assembly constraints, 2D fabrication drawings, or bill of materials (BOM).